Technical documents list
Supplementary documents list
Selection table of actuators
Selection table of actuators on 2-way soft seat ball valves
The table below is a selection table if using an operating pressure at 0.4 MPa based on the following fluid conditions.
The operating pressure varies depending on the rating of the valve unit and seat rating.
Check the fluid pressure because high fluid pressure requires a change in stem material.
The following table is applicable to 2-way soft seat ball valves. It is not applicable to metal or carbon seats.
Fluid conditions A: Clean fluid
Double-acting actuator AD (Compact type)Operating pressure for actuator: At 0.4 MPa
|
Fluid Pressure (MPA) |
Valve Size |
0.5 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
4.0 |
4.5 |
15A |
AD05N |
AD05N |
AD05N |
AD05N |
AD07N |
AD07N |
AD07N |
AD07N |
AD07N |
20A |
AD05N |
AD05N |
AD05N |
AD07N |
AD07N |
AD07N |
AD07N |
AD07N |
AD08 |
25A |
AD05N |
AD05N |
AD07N |
AD07N |
AD07N |
AD07N |
AD08 |
AD08 |
AD08 |
40A |
AD07N |
AD07N |
AD07N |
AD08 |
AD08 |
AD08 |
AD08 |
AD08 |
AD08 |
50A |
AD07N |
AD07N |
AD08 |
AD08 |
AD08 |
AD08 |
AD10 |
AD10 |
AD10 |
65A |
AD08 |
AD08 |
AD08 |
AD10 |
AD10 |
AD10 |
AD10 |
ー |
ー |
80A |
AD08 |
AD08 |
AD10 |
AD10 |
AD10 |
ー |
ー |
ー |
ー |
100A |
AD10 |
AD10 |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
Single-acting actuator AS (Compact type)Operating pressure for actuator: At 0.4 MPa
|
Fluid Pressure (MPA) |
Valve Size |
0.5 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
4.0 |
4.5 |
15A |
AS07N |
AS07N |
AS07N |
AS07N |
AS07N |
AS08 |
AS08 |
AS08 |
AS08 |
20A |
AS07N |
AS07N |
AS07N |
AS08 |
AS08 |
AS08 |
AS08 |
AS08 |
AS08 |
25A |
AS07N |
AS07N |
AS07N |
AS08 |
AS08 |
AS08 |
AS08 |
ー |
ー |
40A |
AS08 |
AS08 |
AS08 |
AS08 |
ー |
ー |
ー |
ー |
ー |
50A |
AS08 |
AS08 |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
65A |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
80A |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
100A |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
Double-acting actuator TD (General purpose type)Operating pressure for actuator: At 0.4 MPa
|
Fluid Pressure (MPA) |
Valve Size |
0.5 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
4.0 |
4.5 |
15A |
TD1 |
TD1 |
TD1 |
TD1 |
TD2 |
TD2 |
TD2 |
TD2 |
TD2 |
20A |
TD1 |
TD1 |
TD1 |
TD2 |
TD2 |
TD2 |
TD3 |
TD3 |
TD3 |
25A |
TD1 |
TD1 |
TD2 |
TD2 |
TD2 |
TD3 |
TD3 |
TD3 |
TD3 |
40A |
TD2 |
TD2 |
TD3 |
TD3 |
TD3 |
TD3 |
TD4 |
TD4 |
TD4 |
50A |
TD3 |
TD3 |
TD3 |
TD3 |
TD4 |
TD4 |
TD4 |
TD4 |
TD4 |
65A |
TD3 |
TD3 |
TD4 |
TD4 |
TD4 |
TD4 |
TD5 |
TD5 |
TD5 |
80A |
TD4 |
TD4 |
TD4 |
TD4 |
TD5 |
TD5 |
TD5 |
TD5 |
TD5 |
100A |
TD4 |
TD4 |
TD5 |
TD5 |
TD5 |
TD5 |
TD6 |
TD6 |
TD6 |
Single-acting actuator TS (General purpose type)Operating pressure for actuator: At 0.4 MPa
|
Fluid Pressure (MPA) |
Valve Size |
0.5 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
4.0 |
4.5 |
15A |
TS1 |
TS1 |
TS1 |
TS1 |
TS2 |
TS2 |
TS2 |
TS2 |
TS2 |
20A |
TS1 |
TS1 |
TS1 |
TS2 |
TS2 |
TS2 |
TS3 |
TS3 |
TS3 |
25A |
TS1 |
TS1 |
TS2 |
TS2 |
TS2 |
TS3 |
TS3 |
TS3 |
TS3 |
40A |
TS2 |
TS2 |
TS3 |
TS3 |
TS3 |
TS4 |
TS4 |
TS4 |
TS4 |
50A |
TS3 |
TS3 |
TS3 |
TS3 |
TS4 |
TS4 |
TS4 |
TS4 |
TS4 |
65A |
TS3 |
TS3 |
TS4 |
TS4 |
TS4 |
TS4 |
TS5 |
TS5 |
TS5 |
80A |
TS4 |
TS4 |
TS4 |
TS4 |
TS5 |
TS5 |
TS5 |
TS5 |
TS5 |
100A |
TS4 |
TS4 |
TS5 |
TS5 |
TS5 |
TS5 |
TS6 |
TS6 |
TS6 |
Fluid conditions B: Powder (not completely filled during operation), slurry, high-viscosity fluid (100,000 CP or more)
Double-acting actuator AD (Compact type)Operating pressure for actuator: At 0.4 MPa
|
Fluid Pressure (MPA) |
Valve Size |
0.5 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
4.0 |
4.5 |
15A |
AD07N |
AD07N |
AD07N |
AD07N |
AD07N |
AD07N |
AD08 |
AD08 |
AD08 |
20A |
AD07N |
AD07N |
AD07N |
AD07N |
AD08 |
AD08 |
AD08 |
AD08 |
AD08 |
25A |
AD07N |
AD07N |
AD07N |
AD08 |
AD08 |
AD08 |
AD08 |
AD08 |
AD08 |
40A |
AD08 |
AD08 |
AD08 |
AD08 |
AD10 |
AD10 |
AD10 |
AD10 |
AD10 |
50A |
AD08 |
AD08 |
AD08 |
AD10 |
AD10 |
AD10 |
ー |
ー |
ー |
65A |
AD10 |
AD10 |
AD10 |
ー |
ー |
ー |
ー |
ー |
ー |
80A |
AD10 |
AD10 |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
100A |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
Single-acting actuator AS (Compact type)Operating pressure for actuator: At 0.4 MPa
|
Fluid Pressure (MPA) |
Valve Size |
0.5 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
4.0 |
4.5 |
15A |
AS07 |
AS07 |
AS07 |
AS07 |
AS07 |
AS08 |
AS08 |
AS08 |
AS08 |
20A |
AS08 |
AS08 |
AS08 |
AS08 |
ー |
ー |
ー |
ー |
ー |
25A |
AS08 |
AS08 |
AS08 |
ー |
ー |
ー |
ー |
ー |
ー |
40A |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
50A |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
65A |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
80A |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
100A |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
ー |
Double-acting actuator TD (General purpose type)Operating pressure for actuator: At 0.4 MPa
|
Fluid Pressure (MPA) |
Valve Size |
0.5 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
4.0 |
4.5 |
15A |
TD2 |
TD2 |
TD2 |
TD2 |
TD2 |
TD3 |
TD3 |
TD3 |
TD3 |
20A |
TD2 |
TD2 |
TD2 |
TD3 |
TD3 |
TD3 |
TD3 |
TD3 |
TD4 |
25A |
TD2 |
TD2 |
TD3 |
TD3 |
TD3 |
TD3 |
TD4 |
TD4 |
TD4 |
40A |
TD3 |
TD3 |
TD3 |
TD4 |
TD4 |
TD4 |
TD4 |
TD4 |
TD5 |
50A |
TD4 |
TD4 |
TD4 |
TD4 |
TD4 |
TD5 |
TD5 |
TD5 |
TD5 |
65A |
TD4 |
TD4 |
TD4 |
TD5 |
TD5 |
TD5 |
TD5 |
TD5 |
TD6 |
80A |
TD5 |
TD5 |
TD5 |
TD5 |
TD5 |
TD6 |
TD6 |
TD6 |
TD6 |
100A |
TD5 |
TD5 |
TD5 |
TD6 |
TD6 |
TD6 |
TD7 |
TD7 |
TD7 |
Single-acting actuator TS (General purpose type)Operating pressure for actuator: At 0.4 MPa
|
Fluid Pressure (MPA) |
Valve Size |
0.5 |
1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
3.5 |
4.0 |
4.5 |
15A |
TS2 |
TS2 |
TS2 |
TS2 |
TS2 |
TS3 |
TS3 |
TS3 |
TS3 |
20A |
TS2 |
TS2 |
TS2 |
TS3 |
TS3 |
TS3 |
TS3 |
TS4 |
TS4 |
25A |
TS2 |
TS2 |
TS3 |
TS3 |
TS3 |
TS4 |
TS4 |
TS4 |
TS4 |
40A |
TS3 |
TS3 |
TS4 |
TS4 |
TS4 |
TS4 |
TS4 |
TS4 |
TS5 |
50A |
TS4 |
TS4 |
TS4 |
TS4 |
TS4 |
TS5 |
TS5 |
TS5 |
TS5 |
65A |
TS4 |
TS4 |
TS4 |
TS5 |
TS5 |
TS5 |
TS5 |
TS5 |
TS6 |
80A |
TS5 |
TS5 |
TS5 |
TS5 |
TS5 |
TS6 |
TS6 |
TS6 |
TS6 |
100A |
TS5 |
TS5 |
TS5 |
TS6 |
TS6 |
TS6 |
TS7 |
TS7 |
TS7 |